Stabiterm

STABITERM 002

24.09.2026

STABITERM 002 is a fire-retardant plaster for structural fire protection of steel and reinforced concrete structures in industrial and civil construction under standard fire conditions. Fire protection — up to R150.

Where to use it

  • steel columns, beams and trusses with high fire-resistance requirements;
  • reinforced concrete structures whose fire resistance needs to be increased;
  • large areas of steelwork — the plaster is applied by mechanized spraying.

How it works

STABITERM 002 is a non-combustible heat-insulating system based on Portland cement clinker with lightweight fillers and special additives. The plaster layer itself insulates the structure from fire and slows down its heating. This is structural fire protection: the protective thickness is created at application.

002 or 003

Both plasters are based on Portland cement clinker and provide up to R150. STABITERM 002 is designed for standard fire conditions — civil and industrial buildings. STABITERM 003 is for oil, gas and chemical sites where the design also requires protection against hydrocarbon fire.

Application

  • By mechanized spraying — on large areas.
  • By hand — on small areas and for repairs.
  • Coating thickness is checked against the fire protection design.

Consumption and coating thickness

We calculate consumption and fire-protective layer thickness for your project: they depend on the required fire-resistance rating and the parameters of each structure. Send us the specification and we will calculate it.

Specifications

Base Portland cement clinker, lightweight fillers, special additives
Protection type structural, non-combustible heat-insulating system
Fire protection up to R150
Fire curve standard
Substrates steel and reinforced concrete
Application mechanized spraying or by hand

Documents

The plaster has Uzbek documents: a fire safety certificate of the Ministry of Emergency Situations of the Republic of Uzbekistan, a certificate of conformity and a quality passport for each batch. Available on request.

FAQ

Is 002 suitable for concrete? Yes, it is designed for both steel and reinforced concrete structures.

How is a plaster different from fire-retardant paint? Paint swells when heated, while plaster insulates the structure straight away with its own layer. Plaster is more robust and covers high ratings — up to R150. For a thin coating, see STABITERM 217.

How much plaster does a project need? It depends on the required fire-resistance rating and the structures. Send us the specification and we will calculate it.

We will calculate the consumption for your project: +998 93 500 09 16, info@stabiterm.uz.

Fire protection across Uzbekistan